Temperature & Humidity Sensors

Please download the catalog 

Temperature Sensors is a resistance Thermometers  are used widely from -200 to +850°C in different process. Especially at low temperature, resistance thermometers are prefered since their accuracy is much better than thermocouples. Up to 400°C standard types and between 400-850°C special types are used. The maximum immersion length of the resistance thermometers should be determined by considering the measurement errors that may be caused by heat transfer occurring along the protecting tube and R/T element. The fluid speed where the resistance thermometer is immersed is a factor affecting the measurement sensitivity. In general, R/T should be perpendicular to the flow direction. Copper conductive cables are used between resistance thermometer head and the instruments. Up to 10 meters, 2×1.5 mm copper cable, up to 150 meters 3×1.5 mm copper cables, after 150 meters 4×1.5 mm coppercable are used.

Straight Thermocouple with metal ceramic protecting tubes are widely used in a variety of processes between -200°C and 1600°C. The maximum operating temperatures given in the catalogue apply to the air where there are no corrosive gases. In general the thermowells chosen for the installation is governed mainly by the corrosion conditions the well will face. The high polish given to all stainless wells provides maximum corrosion resistance. Occasionally, the material consideration is one of the strength rather than corrosion resistance. 

Below are some types of each cateogry.

Thermoresistances

Max. operating temperature: 400°C forBraided wire 200°C for sikicone 260°C forTeflon

Standard cable type: Fiber glass + Fiber glass + Braided wire, 3×0,22 mm² / Silicone + Silicone, 3×0,22 mm² / Teflon + Teflon, 3×0,22 mm( ‘‘Si+Si’’ is added to order code) / (‘‘T+T’’ is added to order code)

Standard cable length (K): K01 = 1mt, K02 = 2mt, K03 = 3 mt, K04 = 4mt, K05 = 5 mt.

Sensor type: DIN/EN60751 Class ‘‘B’’ 1xPt-100 for or 2xPt-100 for (RTR)

Protection tube material: Nickel coated brass (RT) or AISI304 (DIN1.4301),‘‘316’’ is added to order code for AISI316 (RTR)

Connector: ¼ x 19” (selectable as M12” or M12 x 1,5”on ordering)

Fittingnut (RTR): ½’’ fittingnut is used for standard productionraided wire,Silicone,

 

Thermocouples

Max. operating temperature: (TC)-(TCR) 400°C for Braided wire,200°C for Silicone (TCM) ‘‘ J‘’ Type 800°C / ‘‘ K ‘’ Type 1200°

Standard cable types: Fiber glass + Fiber glass + Braided Wire, 2×0,22 mm²Silicone + Silicone, 2×0,22 mm²  ( ‘‘Si+Si’’ is added to order code)

Standard cable length (K): CK01 = 1mt, K02 = 2mt, K03 = 3 mt, K04 = 4mt, K05 = 5 mt.

Sensor type: DIN/IEC-584 ‘‘J’’ FeCu-Ni E=J , DIN/IEC-584 ‘‘K’’ NiCr-Ni E=K

Protection tube material: DIN/IEC-584 ‘‘J’’ FeCu-Ni , DIN/IEC-584 ‘‘K’’ NiCr-N

Connector: ¼ x 19” (selectable as M12”)

Fittingnut (RTR): ½’’ fittingnut is used for standard production

 

Pronem Midi (Duct Type)

Temperature and Relative Humidity Transmitter 

Pronem midi is provided to measure temperature and relative humidity and converts the values standart analog or digital signals for send to another system.

Designed and Developed by RIBS Technologies